Accommodation Pressure Test

Accommodation Pressure Test

The HVAC system of a Temporary Refuge (TR)  should create and maintain a comfortable and safe indoor climate, free of any explosive and/or toxic gas-air mixtures. The air quality and pressure inside the Temporary Refuge are of top priority.

The TR is one example whereby there is a requirement to prepare and operate a written scheme for a system of examination by a competent and independent person and for the recording of such results of that examination. For a Temporary Refuge (TR) onboard a ship or platform, testing is the only practical method due to the higher integrity requirements.

Blower Door Test

The most widely used test of air tightness is a pressure or “blower door” test whereby a fan is used to pressurize an entire ship. The blower door method essentially involves using the door-mounted fan to set the TR to a given reference pressure in its sealed-up state (i.e. the state the TR would be in during an incident). At this reference pressure, the air flow rate through the fan is determined. For most structures, the nature of the leakage paths means that the flow into and out of the structure may not be the same for a given pressure, so the test is carried out for both positive and negative relative pressures. The value of reference pressure may vary according to the application. Testing at higher pressures, for example 50 or 75 Pa, has the advantage that the measurements are relatively independent of the weather conditions at the time of the test. Higher pressures may also be representative of wind driven pressures encountered offshore.

Key feautures

  • Carry out PFEER test
  • Full work pack and risk assessment procured, specific to the job
  • Mobilise to site
  • Complete Leak Testing (If applicable)
  • Complete Test & Site Reporting
  • Demobilise from site/asset

If desired, the check-up report can be accompanied by quotations for recommended work and materials.

More information

If you would like to get more detailed information about the accommodation pressure test, please download the Accommodation Pressure Test brochure or contact us via email.

Contact MRO

ProductsAccommodation Pressure Test
Contact

All fields are required.

We have something interesting for you
Accommodation Pressure Test

Download the brochure for detailed information and technical specifications, free of charge!

Download now

Store locator

storelocator-image2-compressed.png

Go to store locator

Certification

iso9001.pngdnv-gl.pngrrr-2.pngbureau_veritas-2.pngrmrs-2.png
Stay updated

Subscribe to our newsletter

Close
Contact

All fields are required.

Get a quote for an HVAC system

File (optional)
Close
Can't find what you're looking for?

We probably offer a HVAC&R system that suits your specifc needs!