OHVS Borkum Riffgrund 2
Outside35°cHumidity80%
22oInside
Provided byHeinen & Hopman
Our mission is to ensure you the perfect climate indoors, regardless of the weather outside.

HVAC | OHVS Borkum Riffgrund 2

We’re happy to announce that Heinen & Hopman received the order to fabricate and install the HVAC for Borkum Riffgrund 2 Offshore High Voltage Substation (OHVS). Borkum Riffgrund 2 is a German offshore wind farm.

OHVS by HSM Offshore

HSM offshore – a Dutch construction yard experienced in platform, module and jacket projects for the offshore oil & gas and renewables sectors – was awarded the EPC contract for the high voltage AC transformer platform. The Offshore Substation will collect the electrical energy from the offshore wind farm turbines, transform it to a higher voltage level and deliver the power to shore.

ohvs-borkum-riffgrund.jpg

Acceptable air quality and temperature

Offshore substations require a controlled indoor climate to maintain the temperature, relative humidity and air quality within the design limits in order to ensure optimum operation of installed electrical and electronic equipment. By providing ventilation, heating, cooling and moisture control, acceptable air quality and temperature is achieved in all weather conditions. Indoor rooms will be kept at an 50 Pa overpressure in order to avoid infiltration and ingress of salt-particles, dust and saltwater aerosols.

Robust systems

Heinen & Hopman will supply the dehumidification system, the ventilation system (including natural ventilation), the heating & cooling system as well as the HVAC control systems. Robustness was one of the key requirements. High quality materials will be used to avoid corrosion and guarantee the 25 year lifetime of the platform. For example, only stainless steel ducting and piping will be used, as well as self-contained units with air cooled condenser coils made of titanium.

Design conditions

The following design conditions are considered:

Summer conditions

Outside: 25˚C/70%RH
Inside: 20-30˚C*/40%RH

Winter conditions

Outside: -10˚C/70%RH
Inside: 10-23˚C*/40%RH

* pending manned/unmanned situation

More information

If you would like to get more information about our HVAC solutions for Offshore High Voltage Substations, please don’t hesitate to get in touch.

contact us

 

Read more

Subsidiary
Heinen & Hopman HQ
Shipyard
HSM Offshore
Name
OHVS Borkum Riffgrund 2
Type
Offshore High Voltage Substation (450 MW)
Delivery year
2018
Country of Delivery
The Netherlands