Dampers HT

Home
Products
Dampers HT

Fire and gas dampers

Fire and gas dampers prevent the spread of fire, smoke and gas between fire zones, where people must have the maximum amount of time to react to possible fire. The dampers are type-approved according to A0 (A60) or H0 (H120).

Download brochure  Contact us

The patented blade structure of the FDB2 dampers have special seals that are effective up to 300 °C and thermally activated graphite seals that expand when the heat rises to 150 °C in ductwork. These unique safety features ensure air tightness and low leakage to prevent fire, gas and smoke progression in a ductwork.

Shut-off dampers

Shut-off dampers shut off the airflow in ductwork where tightness, thermal insulation and reliability are important. The dampers meet international standards for rectangular and circular ducts. The leakage class is accordance with the EM1751 standards.

Balancing dampers

Balancing dampers adjust or control the air flow rates in ductwork where leakage does not have significant importance.

Non-return dampers / Pressure relief dampers

Non-return dampers and pressure relief dampers are used in oil and gas applications to prevent backflow and relieve the pressure through ventilation ductwork. The opening pressure can be individually adjusted. The dampers are also applicable in marine ventilation systems.

Blast dampers

Blast dampers protect ventilation systems against the effects of explosions. The dampers shield industrial facilities and related buildings against destructive blast forces. The dampers offer higher air flow capacity and increased level of safety as well as flexibility for design of duct systems.

Air flow adjustment dampers

PRA air flow adjustment dampers are manually adjustable measurement units for circular ducts. The dampers are used in duct systems to control the air flow.

Control

The dampers can be controlled electrically, pneumatically or manually. In case of fire, the fire and gas dampers will close automatically. The electrically and pneumatically controlled dampers are driven by an actuator.

  • Belimo actuators: as standard actuator.
  • Schischek actuators: actuator used in explosion-proof areas or if the actuator must open/close within 3 s/90°.

More information about Dampers HT

Don’t hesitate to contact us for more information about our Dampers HT. Our skilled engineers are eager to explain the possibilities for your vessel or structure.

Download the Dampers HT brochure for detailed information and technical specifications.

Brochure

Dampers – HT

Fire and gas dampers prevent the spread of fire, smoke and gas between fire zones, where people must have the maximum amount of time to react to possible fire.

Looking for a custom solution?

Don’t hesitate to contact us for advice for your specific needs.

Call +31 (0)33 299 2500